Electrical Supplies

Data-LAN & Telephone cables

Data-LAN & Telephone cables

Supplied by

  • Ramcro Italy
  • PAIGE USA
  • 2MKablo
  • Turkuaz Kablo

About

  • For data & signal transmission (Cat 5, CaT 6, Cat 6A, Cat 7, Cat 7A, RS485, RS422, RS232, MODBUS, M-BUS, LANWORKS Telephone Applications).

Application

These cables are used for data & signal transmission in RS485, RS422, RS232, MODBUS, M-BUS, LONWORKS, Telephone Applications.

Standards & Reference 14 cited

  • ANSI/TIA-568-C.2

    The American cabling standard for balanced twisted-pair components, which is where Category 5e, 6 and 6A come from.

  • IEC-61156-5

    Multicore and symmetrical pair cables for data transmission in horizontal structured cabling.

  • IEC-11801

    The international standard for generic structured cabling in customer premises: the class ratings a network installation is certified to.

  • EN-50173-1

    The European generic cabling standard for information technology systems, the regional counterpart to ISO/IEC 11801.

  • EN-50288-10-1

    Screened cables for use up to 500 MHz, within the European multi-element metallic cable series.

  • BS EN 50290-2

    Common design and construction rules for communication cables: the materials and build quality expected of data, signal and instrumentation cable.

  • IEC 60332-1

    Flame propagation on a single vertical cable. It shows the cable will not carry a fire along its own length, which is the minimum expected of any cable in an occupied building.

  • IEC 60332-3-24

    Flame spread on a bundle of cables in a vertical tray, Category C. A cable can pass the single-cable test and still spread fire when hundreds are bunched in a riser, which is what this addresses.

  • IEC 60754-1

    How much halogen acid gas the cable gives off when it burns. Halogen-free matters where people or sensitive equipment share the space with the cable.

  • IEC 60754-2

    The acidity and conductivity of the gases a burning cable produces: in effect, how corrosive the smoke is to the building and its equipment.

  • IEC 61034

    Smoke density from a burning cable, measured in a sealed chamber. Low smoke is an evacuation requirement: people leave a building by sight.

  • EIA / TIA 232-422-485

    The American cabling standard for balanced twisted-pair components, which is where Category 5e, 6 and 6A come from.

  • RoHS Compliant

    Made within the restrictions on lead, mercury, cadmium and the other hazardous substances the EU limits in electrical equipment.

  • UL Certified

    Carrying UL certification against the relevant product safety standard.

Documents

Request for quotation

Get a price for this item

Send the quantity and the project. Our sales engineers reply with a quotation, usually within one working day.

More in this line

Special Cables

8 products

View All