Mechanical Supplies
Ceiling Isolation Products
About
- Kinetics IsoMax isolation clips and spring hangers supporting steel grid and gypsum board ceilings. A soft neoprene isolator cradles the hat channel so structure-borne vibration is not transferred into the channel and from there into the board, two layers of board on isolated hangers typically add 8-12 dB over a directly fixed ceiling.
Application
Used below plant rooms, car park ramps, gyms and noisy tenancies, and in hotel and residential work where footfall from the floor above is the complaint. Services fixed through the isolated ceiling, sprinkler drops, luminaires, duct hangers, must be isolated too, or each one becomes a rigid bridge that carries the noise straight past the ceiling installed to stop it.
Standards & Reference 5 cited
ASTM E90
The laboratory measurement of airborne sound transmission loss: the raw data a partition's acoustic rating is derived from.
ASTM E413 (STC)
Sound Transmission Class: the single number that summarises an ASTM E90 measurement, used to compare partitions and doors.
ASTM E492
Impact sound transmission: the footfall equivalent of ASTM E90, summarised as an Impact Insulation Class.
ASTM E84
Surface burning characteristics: the flame spread index and smoke developed index a material is classified by. Class A is the usual requirement in an occupied building.
Also citedASTM C635 / C636
Request for quotation
Get a price for this item
Send the quantity and the project. Our sales engineers reply with a quotation, usually within one working day.
More in this line
Noise Control & Room Acoustics
10 products
View All